Thermal aging test box

Reference Price ¥ 5000
order amount 1 piece

Other products of this manufacturer

I want to be here too

The heat aging test box is a series of products modified from the original series. After the product is modified, it is energy-saving, beautiful and practical, with two specifications of 100 liters and 140 liters.


Beiguang Precision Instrument Co., Ltd. is a high-tech company specializing in the production of testing instruments and automation equipment.
"Being refined and exquisite," is the principle that Beiguang Precision Instrument has always been adhering to. Its advanced design style, excellent manufacturing technology and perfect service system provide scientific research institutions, colleges and universities, enterprises and quality inspection institutions with a comprehensive range of products and quality services.
Beiguang Company maintains the main line of developing application technology that is compatible with China's testing industry, and improves the company's competitive strength and technological content through coordinated development with the industry.
At the same time, since its establishment, the company has adhered to the combination of "R & D and production". With the knowledge of the National Institute of Industry and strong scientific research, it has boldly innovated, digested and absorbed international advanced production technology. Forging ahead with reforms and innovation, we have developed new products with Chinese characteristics and made due contributions to improving China's scientific research and product quality.
Business philosophy:
First, the integrity of the customer is the supremacy of the customer. We will consider the customer wholeheartedly, so that the customer can feel the humanized instrument.
2. Accurate detection, quality and quantity Accurate detection is our responsibility, quality and quantity is our solemn promise to customers
III. Innovation Idea of Technology Leader Xian reserves the development talents who have stayed for a while, introduces world leader xian technology, and adopts advanced design concepts to create the most excellent testing instruments.
Beiguang products are widely used in national defense, colleges and universities, testing institutes and other industries. The company takes technological innovation as the development direction of the company and guides customers' needs with new and practical products. The products supplied by Beiguang are manufactured strictly in accordance with national standards. The rigorous manufacturing process ensures the outstanding quality and performance of each factory instrument, high quality service, high quality and low price to ensure your peace of mind!

Use For industrial and mining enterprises, laboratory research units for aging, drying, baking, melting wax, sterilization.

I. Main data of thermal aging test chamber
Temperature range 10-300 ℃
Temperature fluctuation ± 1 ℃
Power supply voltage 220V
Power consumption: 2000W

Structure Overview of Thermal Aging Test Chamber
It is a series of products after the modification of the original series of products. After the modification of this product, it is energy-saving, beautiful and practical, with two volumes of 100 liters and 140 liters. Non-specifications can be specially processed according to user requirements. The outer casing of all specifications of the aging test box is welded with high-quality steel plates and the surface is baked. The inner steel plate is sprayed with temperature-resistant silver powder paint or stainless steel. 50% of the shelves. A support turntable is installed in the middle, and the insulation layer is insulated with ultra-fine glass wool. The box door is equipped with double-glazed observation windows, and the joint between the studio and the box door is equipped with a heat-resistant asbestos rope to ensure the seal between the studio and the box door. The operating parts such as the power switch and temperature controller of the aging test box are concentrated in the control place on the left side of the front of the box, and operate according to the indicator.
The heating and constant temperature system in the box is equipped with a fan, an electric heater, a suitable air duct structure and a temperature controller. When the power is turned on, the fan runs at the same time. The heat generated by the electric heating directly placed in the back of the box passes through the air duct. Circulating air is formed, and the dried articles are drawn into the fan through the working room, so that the temperature is evenly circulated.
The temperature controller is an intelligent digital display, with high temperature control accuracy, a set temperature with a protective device and a timing function.

Third, use
1. Put the dried items into the aging test box, and close the door and then turn on the power.
2. Turn the power switch to 'On'. At this time, the power indicator lights up and the digital temperature controller has a digital display.
3. See Appendix 1 for the setting of the temperature controller. The temperature controller shows that there is temperature in the box. Generally, the temperature control enters a constant temperature state after heating for 90 minutes. (Note: Refer to the 'Operation Method' below for intelligent temperature controller)
4. When the required working temperature is relatively low, the secondary setting method can be used. If the working temperature is 80 ° C, the first setting can be 70 ° C. When the temperature overshoot falls, set the second time to 80. ℃, which can reduce or even eliminate the temperature overshoot, so that the temperature in the box enters the constant temperature state as soon as possible.
5. Choose different drying temperature and time according to different items and different humidity levels.
6. After drying, turn the power switch to "OFF", but you cannot open the box door immediately to take out the items. Be careful of burns, you can open the box door to reduce the temperature inside the box before taking out the items.

Fourth, matters needing attention
1. The box enclosure must be effectively grounded to ensure safe use.
2. Turn off the power after use.
3. There is no explosion-proof device in the aging test box. Do not put flammable and explosive items.
4. The aging test box should be placed in a room with good ventilation, and no flammable and explosive items should be placed around it.
5. Do not overcrowd the items in the box. You must leave space to facilitate the circulation of hot air.
6, inside and outside the box should always be kept clean.
7. When the operating temperature is between 150 ℃ ~ 300 ℃, the box door should be opened to reduce the temperature inside the box after shutdown.

Product model and specifications
1. Product model: YF-150
2. Studio size (mm): D500 × W500 × H500
Technical parameters
1. Temperature range: RT + 10 ℃ ~ 60 ℃
2. Ozone concentration: 25 ~ 1000pphm direct reading adjustable
3. Temperature uniformity: ≤ ± 2 ℃
4. Temperature fluctuation: ≤ ± 0.5 ℃
5. Temperature deviation: ≤ ± 2 ℃
6. Deviation of ozone concentration: ± 10% pphm
7. Ozone sample rack: with static tensile test sample rack (product elongation 0 ~ 100%)
8. South Korea imported "Sanyuan" ST190 instrument, PID intelligent control, precise temperature control, strong ability to suppress temperature overshoot.
Third, the box material Outer box material: cold-rolled plate electrostatic spraying, uniform and beautiful color, increased appearance texture and cleanliness Inner box material: SUS304 imported high-end stainless steel plate Fourth, ozone system
1. Ozone concentration controller: LED display controller
2. Measuring range: 25-1000pphm
3. Resolution: 0.02ppm
4. Maximum allowable error: ≤ ± 1% FS
Repeatability: not more than 1/2 of the absolute value of the indication error
5. Stability: Zero drift ≤ ± 1% FS / 7d
Range drift ≤ ± 1% FS / 7d
Insulation strength: between the instrument power line pair and the instrument case, no breakdown or flashover for 1min at 1500V AC voltage
6, voltage change: voltage change 1%, the error is not greater than 1/2 of the absolute value of the error
7. Pressure range: atmospheric pressure ± 10%
8. Ozone generator: Beijing "Tianhua" voltage silent discharge tube
9. Electrode cooling method: air cooling
10. Ozone generation air supply source: air
11. Ozone concentration detection sensor: "Tianlang" imported from Britain
12.The collection accuracy of ozone detection probe is ≤ ± 5% FS
V. Attachments
1. Equipped with four universal wheels for box movement (optional)
2. The window is made of hollow special high-resistant tempered glass (with lighting)

Standards compliant:
GB / T7762-2003 Vulcanized rubber or thermoplastic rubber resistance to ozone cracking static tensile test method
GB / T2951.21-2008 General test method for cable insulation and sheath materials,
GB / T 11206-2009 Surface cracking method for rubber aging test;
And other relevant test methods.
National standard profile: Vulcanized rubber or thermoplastic rubber resistance to ozone cracking static tensile test GB / T 7762-2003
This standard specifies test methods for resistance to ozone cracking when vulcanized rubber or thermoplastic rubber is exposed to air with a certain concentration of ozone under static tensile strain conditions and in an environment at a specified temperature without direct effects of light.
The ozone resistance of different rubber materials varies significantly with ozone concentration and temperature. The ozone strain test of tensile strain samples and the degree of damage caused by ozone during the use of products are very different due to the difference in size, type and strain.
Notes on ozone cracking properties can be found in Appendix A

After-sale service
After sales content:
Our company sends engineers to be responsible for installation, debugging and training.
Products from the date of customer acceptance, free warranty for 2 years, life-long maintenance.
1. Equipment installation and commissioning:
Provide free installation and debugging services for users. Before installation and commissioning, the user shall provide corresponding preparations and give advance notice. The specific installation and commissioning date can be determined by both parties through consultation. The equipment installation and debugging are carried out by senior engineers for many years free of charge. Ensure that the user can use the software correctly, operate and maintain the software, and deal with the faults.
2. Training:
Our company's engineers provide free operator training for users until the operators can operate independently.
3. Equipment acceptance standard:
The user shall conduct acceptance according to the order technical requirements. And meet the requirements of national standards. The equipment acceptance shall be conducted by the user side, and the installation and commissioning technicians of our company and the user shall jointly sign the maintenance report to confirm the completion of the instrument commissioning.
4. Equipment maintenance service:
Our company's products are free of charge for warranty and lifetime maintenance within 2 years after the user's on-site commissioning and acceptance. During the 2-year free warranty period, our company provides free maintenance for customers in case of non-human quality problems. If the product breaks down outside the free warranty period, the maintenance service will only charge the material cost properly.
5. Technical support:
For the users of required instruments, professional technical solutions shall be provided according to the requirements of users. In addition to conventional instrument services, our company's technical department can also provide users with technical support for various unconventional equipment.
6. After sales response:
After receiving the user's maintenance invitation, respond within 2 hours and solve it. If it is not solved, our company will assign engineers to arrive at the user's site in time to solve the problem until the equipment is in normal use.



Back to 彩乐乐网