window._bd_share_config = { "common": { "bdSnsKey": {}, "bdText": "", "bdMini": "2", "bdMiniList": false, "bdPic": "", "bdStyle": "0", "bdSize": "16" }, "slide": { "type": "slide", "bdImg": "0", "bdPos": "left", "bdTop": "123.5" }, //"image":{"viewList":["qzone","tsina","tqq","renren","weixin"],"viewText":"分享到:","viewSize":"16"}, share : [{"tag":"share_1","bdSize" : 16}]};with(document)0[(getElementsByTagName('head')[0]||body).appendChild(createElement('script')).src='/static/api/js/share.js?v=89860593.js?cdnversion='+~(-new Date()/36e5)];
Product showroom collection of the shop

Hello Login Registration

current position:
Fujian Shunchang Hongrun Precision Instrument Co., Ltd. > Smart Isolator > Isolator > NHR-X31 Intelligent Isolator

Smart Isolator

Back to list page
  • Smart Isolator

  • Smart Isolator

  • Smart Isolator

  • Smart Isolator

  • Smart Isolator

Favorite Report
price Negotiable
  • NHR-X31 Model NHR-X31
  • Brand
  • 生产商 Manufacturer nature
  • 南平市 LocationNanping

Updated: 2019-11-05 10:08:04 Views: 832

When you contact us, please indicate that the information you see on Plastic Machinery Online, thank you!

Product introduction

The rail-type intelligent isolator transmits the on-site DC voltage or current signal through isolation and converts it into the required signal for other instruments. It can be used in conjunction with the unit combination instrument and DCS, PLC and other systems to give field instrument signal isolation, signal conversion, signal distribution, signal processing, etc., thereby improving the anti-interference ability of the automatic control system in the industrial production process and ensuring system stability and reliability Sex. With display unit, you can set the parameters of each channel and switch between each channel by touching the keys.

Detailed introduction

 

Smart Isolator

Single-channel, dual-channel.
It can measure 16 kinds of DC voltage (millivolt) / current signals. Users can set any input type according to their needs.
Analog, RS485 output.
Input / output / power magnetic isolation.
Transmission accuracy (20 ℃): 0.2% FS ± 1 word.
The response time reaches 50% of the final value in 50ms.
Wide power supply (AC / DC20-260V).
Fully intelligent, digital and programmable.
Plug-in terminals for easy installation and maintenance.
Standard 35mmDIN rail card installation.
Programmable high-definition display unit can realize PV (measured value) and SV (output value) display on the same screen. The display content can be set according to menus and various combinations, which is convenient for on-site debugging, maintenance and troubleshooting of equipment.
Smart Isolator Overview
The on-site DC voltage or current signal is transmitted through isolation and converted into the required signal to other instruments.
It can be used in conjunction with the unit combination instrument and DCS, PLC and other systems to give field instrument signal isolation, signal conversion, signal distribution, signal processing, etc., thereby improving the anti-interference ability of the automatic control system in the industrial production process and ensuring the stability and reliability of the system Sex.
With display unit, you can set the parameters of each channel and switch between each channel by touching the keys.
Wiring diagram


Structural outline drawing


Technical Parameters

Enter
input signal DC voltage and current signals (users can set any input type as required)
input resistance Current impedance ≤50Ω, voltage impedance ≥250KΩ
Large amount of input current / voltage ≤30mA / ≤10.5V
Output
output signal 4-20mA, 0-10mA, 0-20mA, 1-5V, 0-5V
Output load 4-20mA, 0-10mA, 0-20mA load resistance RL≤500Ω; 1-5V, 0-5V load resistance RL≥250KΩ
RS485 communication MODBUS-RTU protocol, RS485 transmission distance ≤1000 meters; signal transmission rate ≤19.2kbps
power supply
power supply DC / AC20-260V (50 / 60Hz)
Power consumption One-in-one-out power consumption: ≤1W; One-in-two-out, two-in-two-out power consumption: ≤1.4W
Other parameters
Insulation resistance
(Between input / output / power)
≥100MΩ (at 500VDC)
Dielectric strength
(Between input / output / power)
1500Vrms (1 min, no spark)
Operating temperature -10 ~ 50 ℃ (no condensation, no icing)
Relative humidity 25% ~ 85% RH
Storage temperature -10 ~ 60 ℃ (no condensation, no icing)
Temperature drift 0.0075% FS / ℃
Installation method 35mmDIN rail mounting
Installation size 17.5 * 111.4 * 121.2mm (width * height * depth)
Transmission accuracy (20 ℃) 0.2% FS ± 1 word
Response time 50ms reaches 90% of final value
weight Approximately 140 grams
Electromagnetic compatibility Meets GB / T18268 industrial equipment application requirements (IEC 61326-1)
Applicable field equipment DC voltage / current source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instrument selection

Remarks:

When RS485 communication is selected for output I, there is no output II function.

Model example: NHR-X31-27 / 27-0 / 0-A

, The dual input signal is 4 ~ 20mA, the dual output signal is 4 ~ 20mA, and the power supply DC / AC20 ~ 260V.

The above information is provided by the enterprise itself, and the authenticity, accuracy and legality of the information content are the responsibility of the relevant enterprise. Plastic Machinery Network does not assume any responsibility for this.
Tips: In order to avoid purchasing risks, it is recommended that you confirm the supplier's qualification and product quality before purchasing the product.
or

Favorite the shop

Please log in before collecting

prompt

Your message has been submitted successfully! We will reply you as soon as possible ~
Product comparison Phone QR code Feedback online chating

Scan to visit mobile phone shops
****** 599-7821390,7852057,7852831,7824386
Leave message